top of page

DRYMIX MORTAR SERIES

CNG-770
Non-Shrink Grout MP

A multi-purpose (flowable and dry pack), shrinkage-compensated grout. It is designed to fill up gap and holes for concrete. This product is free of chlorides and other substances that could contribute to the corrosion of reinforcing steel or pre-stressing steel cables. Engineered for uniform mixing, it effectively minimizes segregation and bleeding. It's suitable for anchoring and requires only the addition of water to create an easily applied, free-flowing grout.

CNG-770_edited.png

Usage Calculator

*The calculated results are for reference only. Please reach out to our team for further assistance.

PRODUCT USES

Non-shrink, chloride-free, fast setting (<7 hours), multi-consistency application

Pink Poppy Flowers

Fills precast gaps, core holes, concrete defects.

Pink Poppy Flowers

Flowable grout for hollow block walls

Pink Poppy Flowers

For concrete anchors, rail beds, foundations

PRODUCT BENEFITS

sasun-bughdaryan-Re1O5byZ8bY-unsplash.jpg
63bdcd70-ae6c-44b9-bf1f-5ee8f4fcb55e_edited.png

Shrinkage

Compensated 

​

Helps reduce the risk of shrinkage cracks.

Rapid

Setting

​

Setting time of less than 7 hours..

Pink Poppy Flowers
Pink Poppy Flowers
Pink Poppy Flowers

Chloride-free Formulation

 

Safe for use with steel reinforcement components.

Pink Poppy Flowers

Versatile

Application

 

Suitable for dry packing, troweling, and pouring.

Pink Poppy Flowers

High 

Strength

 

Exhibits high early strength and long-term durability

PERFORMANCE DATA SHEET

Criterias
Dry Pack
Plastic
Fluid
Water demand (%)
14 – 15%
16 – 17%
20 – 22%
Water demand (L/25 kg bag)
3.5 – 3.8 L
4 – 4.2 L
5.0 – 5.5 L
Yield
12.5 L
13 L
13.5 L
Compressive strength
75 N/mm2*
70 N/mm2
60 N/mm2
Expansion at 24 hours (ASTM C 827)
1 - 4%
/
0 - 4%
Expansion at 28 days (ASTM C 1090)
0 – 0.4%
/
0 – 0.4%
Flow of Grout (ASTM C 939)
/
/
< 35 seconds
Setting Time (ASTM C 953)
< 7 hours
/
< 7 hours
Chloride Content (BS 1881 : Pt 124 : 1988)
< 0.1%
/
< 0.1%
Figg Air Permeability (HKHA MTS TM6)
> 200 seconds
/
/
Notes
Unless specified, all technical data refers to 28 days curing time
*Product certification PCCS-RM Issue 2 2017 Class S (fcu = 60MPa)

Above physical data are from laboratory tests. Actual field performance may vary due to environmental conditions and workmanship factors beyond the manufacturer's control.

Previous Item
Next Item

Need help slecting the right product for your project?

Our technical team can support specification, application and system recommendations

bottom of page