top of page

DRYMIX MORTAR SERIES

PBM-19
EVA Mix

A high-performance liquid admixture based on ethylene vinyl acetate, specifically formulated to enhance Ordinary Portland Cement (OPC) as a concrete surface modifier. This product significantly improves the adhesion of renders, plasters, and floor screeds to various building surfaces.

Pink Poppy Flowers

Usage Calculator

*The calculated results are for reference only. Please reach out to our team for further assistance.

PRODUCT USES

EVA admixture enhances cement base adhesion and acts as surface modifier

Pink Poppy Flowers

Admixture for tile adhesion

Pink Poppy Flowers

Act as concrete surface modifier

Pink Poppy Flowers

Enhance adhesion strength of mortar and spatterdash

PRODUCT BENEFITS

pexels-tima-miroshnichenko-6474197 (1).jpg
Pink Poppy Flowers

Excellent substrate bonding

Adheres well to concrete, masonry, and panels.

Pink Poppy Flowers

Adhesive Strength and Cohesive Strength

Provide extra flexibility, adhesive strength to tile adhesive and cohesive strength to mortar

Pink Poppy Flowers

Chloride-free formulation 


Safe for use with steel reinforcement components

Pink Poppy Flowers

Surface modifier for adhesion

 

Enhances adhesion of render and screed layers.

Pink Poppy Flowers

Improves mortar cohesion

Strengthens the internal bonding of mortar mix

PERFORMANCE DATA SHEET

Criterias
Bonding Slurry
Spatterdash
GREENTECH EVA MIX PBM-19
50 KG
10 KG
Cement
50 KG
50 KG
Sand
-
100 KG
Water
-
30 KG
Consumption (L/m²)
0.17 – 0.2 L/m²
0.06 – 0.12 L/m² **
Coverage (m²/L)
5 – 6 m²/L
7 – 17 m²/L
Adhesion to Concrete
> 1.0 N/mm²
> 1.5 N/mm²
Compressive Strength
> 20.0 N/mm²
> 25.0 N/mm²
Flexural Strength
> 6.0 N/mm²
> 7.0 N/mm²
Notes
Unless specified, all technical data refers to 28 days curing time
Spatterdash consumption may vary highly depending on spreading pattern.
Criterias
Rapid Fix CFF-978
Supreme Fix CTF-888
Tile Adhesion
40 KG
40 KG
PBM-19
7 – 8 L
7 – 8 L
Water
7 – 8 L
7 – 8 L
Deformability
S2
S2
Adhesion Strength
> 2.8 N/mm²
> 2.5 N/mm²

Above physical data are from laboratory tests. Actual field performance may vary due to environmental conditions and workmanship factors beyond the manufacturer's control.

Previous Item
Next Item

Need help slecting the right product for your project?

Our technical team can support specification, application and system recommendations

bottom of page